Topcon sp-3000p
Webthe SP-3000P in a category of its own, incorporating features and specifications that fully meet the needs of the demanding practitioner. Measuring endothelial cell ... and interfacing with other Topcon instruments such as Slit lamps and Retinal cameras. 1. Alignment Wider auto alignment simplifies the capturing procedure. Just WebNoncontact Specular Microscope Sp 3000p, supplied by topcon corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, …
Topcon sp-3000p
Did you know?
WebNon-Contact: The SP-2000P captures the image of the endothelium cells and calculates cornea thickness by a unique method that does not require touching the cornea. This patented procedure eliminates the risk of transmitting infectious disease and reduces potential physical injury to the eye. Patient comfort is increased. Web1. júl 2024 · Topcon SP3000P non-contact endothelial specular microscopy (NCSM) (Topcon Corporation, Tokyo, Japan) was used for endothelial and pachymetric analysis. …
Web22. nov 2016 · Topcon SP-3000P provides similar systematic bias in comparison with US technique for CCT measurements regardless of the degree of corneal edema after phacoemulsification, which should be reduced after applying a constant calibration adjustment of ∼30 μm.
WebPurpose: To compare and analyze the interchangeability of three measuring systems, each based on a different technique, for central corneal thickness (CCT) analysis. Methods: … WebSP-3000P with Notebook PC and CellCount Software Complete digital configuration of SP-3000P. The Cell Analysis Software installed in IMAGEnet™ provides superior analysis …
WebPurpose: To compare the effect of tetracaine 1% on central corneal thickness (CCT) measurements obtained by the ultrasound pachymetry (USP) and Topcon SP-3000P specular microscope. Methods: In the following sequence, SP-3000P before anesthesia, USP before anesthesia, SP-3000P 10 mins after anesthesia, USP 10 mins after …
WebSP-3000P with PC, IMAGEnetTM Cell Analysis Software Complete digital configuration of SP-3000P. The Cell Analysis Software installed in IMAGEnetTM provides superior … phonepay helpWeb13. jan 2024 · SP-3000P: An overestimation in the cell count area resulted in an underestimation in ECC of 1.4%. ... In this paper, we discuss an interchangeability problem between two CSMs, the Topcon SP-2000P and SP-3000P, manufactured by the same company (Topcon Medical Systems). The interchangeability concern in our case was … how do you spell the number 50http://www.1mmed.com/Ourproduct/ourproduct4/pid/191 phonepay hiringWeb21. jan 2013 · Abstract Purpose: To compare the effect of tetracaine 1% on central corneal thickness (CCT) measurements obtained by the ultrasound pachymetry (USP) and Topcon SP-3000P specular microscope. Methods: In the following sequence, SP-3000P before anesthesia, USP before anesthesia, SP-3000P 10 mins after anesthesia, USP 10 mins … phonepay iconWeb24. jún 2011 · Aim: To compare the precision of the Topcon SP-3000P noncontact specular microscope (NCSM) and the DGH 500 ultrasound pachymeter (USP). Methods: Triplicate … how do you spell the sound of a whistlehttp://www.mehraeyetech.in/pdf/topcon/sp_3000p.pdf how do you spell the spanish name joseWeb24. jún 2011 · Aim: To compare the precision of the Topcon SP-3000P noncontact specular microscope (NCSM) and the DGH 500 ultrasound pachymeter (USP). Methods: Triplicate measurements of central corneal thickness (CCT) for 100 eyes were taken with an NCSM and a USP in 2 visits separated by 1 week. how do you spell the twins