Ladbs retaining wall height
Web7010.1 Height. No cut slope shall exceed a vertical height of 100 feet (30.48 m) unless horizontal benches with a minimum width of 20 feet (6.096 m), as shown in Figure D of … WebHome Department of City Planning, Los Angeles
Ladbs retaining wall height
Did you know?
WebDivision (LADBS-GD) will process documents during the temporary office closure. Please note that these procedures may be modified to suit specific conditions. LADBS established “Drop-off/Pick up” areas at the Figueroa Plaza (Metro), Marvin Braude Building (Van Nuys), and the West Los Angeles office (Sawtelle). ... WebCONCRETE BLOCK RETAINING WALL (H=6'-0 MAX) B3761-1, B3761-2: Back to Standard Plans Main Index ...
WebOct 25, 2012 · walls and retaining walls supporting more than 6 feet (1.83 m) of backfill height due to design earthquake ground motions. Due to the variability in soil properties … WebAug 5, 2024 · The retaining wall drainage system prevents the build-up of hydrostatic water pressure which can cause flooded basements and foundation damage. It is common to refer to this system as a French Drain. Surface conditions are extremely important when installing a post-applied waterproofing system. Small bubbles, voids, or raised areas will cause ...
WebFeb 4, 2024 · Is the height of the proposed retaining wall greater than 6' (standard plan only allows for up to 6') If the soil isn't capable of supporting Toe Pressure Loads, a special … WebMar 22, 1999 · The fences may be supported by solid six-foot high pilasters with a maximum dimension of 24 inches and spaced not less than eight feet apart on center. 3. No vertical wrought iron member shall be greater than 5/8 inches in diameter nor spaced less than four inches apart on center. 4.
Webretaining walls supporting more than 6 feet of backfill shall be designed for seismic lateral earth pressures due to design earthquake ground motions. The seismic lateral earth …
WebOct 25, 2012 · Section 1705.4 except for those retaining walls (cantilever and restrained) with one of the following conditions: a. Case 1 and 2 where retaining walls are accessory to a residential occupancy. b. A stem wall height less than 6 feet 10-inches measured from top of footing to top of stem wall where the allowable design masonry stresses rac0509Webaddress height measurement, or buildings regulated by LAMC Section12.21A.17 of this Code. Refer to the Zoning Manual for additional restrictions. g. Architectural projections … dora ulazniceWebOct 8, 2024 · The allowable height of fences, walls (non-retaining) and gates are stipulated in the Zoning Code and the public right of way should not be used to circumvent private … dora usluge zagrebWebDec 14, 2024 · 6” concrete block masonry wall detail (6’-0” height maximum) on side and rear yard as indicated in the site plan per ladbs standard detail and specifications document no..: p/bc 2024-096 Valuation: N/A Permit #: 20020-10000-01849 Status: triage Fee: N/A Permit Type: 1 or 2 family dwe... Building Type: N/A Bldg-alter/repair rac05-05sk/pd3/hhttp://baycitygeology.com/images/IB-P-ZC_2002-016_Retaining_Walls_in_Hillside.pdf dora uzivoWebFENCE CONSTRUCTED ATOP RETAINING WALL Item 2 of Section 106.3 states, a building permit is not required for fences of 6-feet or less in height. ... Retaining Wall 6 Ft. Max Overall Height Supersedes BCM 106.3 Article 1, dated 06-14-11 #001 - 106.3 Article 1 BUILDING CODE MANUAL Page 2 of 2 rac05-05skWebOpen railings up to 48 inches high placed on top of a retaining or other wall and required for pedestrian safety may be permitted if an increase in height is approved per subsection (J) of this section. I. Residential Entry Gates. dora uzinić